+98-2177160794

S-200



  This type of sensor has been designed for microseismic events recording during hydraulic fracturing reservoir experiments. The sensor body has been designed in order to house double geophone strings at each axis. The orientation follows the 3-axis principle. This sensor has an external diameter of 50mm allowing it to be installed into small and shallow boreholes, hence reducing the cost of installation. Using single geophone element per axis, the electronic noise floor becomes a limiting factor for this type of acquisition. Increasing the gain and minimizing the noise floor of the sensor give us the ability to record even smaller events.



Brochure








Characteristics:
MODEL S200A (without  electronics)
Number  of channels: 3channels, Vertical, North-South, East-West
Channel Resistance 6800 OHms
Sensitivity 184 V/m/s
Natural Frequenc y 4.5Hz (10Hz, 14Hz, 28Hz, 35Hz under  request)
Open circui t damping 0.76
Cable length Standard 20m, up to 200m
Size 460mm length, 50mm diameter
Weight (geophone enclosure) 3400g
MODEL S200B (with preamplif ier)
Number  of channels: 3channels, Vertical, North-South, East-West
Output Resistance 500 OHms
Sensitivity 1500 V/m/s
Natural Frequenc y 4.5Hz (10Hz, 14Hz, 28Hz, 35Hz under  request)
Power 12Vdc, 41mA (0.49W)
Cable length Standard 20m, up to 200m
Size 460mm length, 50mm diameter
Weight (geophone enclosure) 3400g
Number  of channels: 3channels, Vertical, North-South, East-West
Output Resistance 500 OHms
Sensitivity 1500 V/m/s
Natural Frequenc y 1Hz (0.5Hz, 0.2Hz under  request) 
Power 12Vdc, 43mA (0.49W)
Cable length Standard 20m, up to 200m
Size 460mm length, 50mm diameter
Weight (geophone enclosure) 3400g
ALL MODELS GENERAL CHARACTERISTICS
Mass lock , centering Not required
Temperature range -20 to +70oC
Humidity 100%, IP67 enclosure
Submersible 1000 meters